boiler-controller-mock-server

Mock server that simulates the Boiler Controller firmware API.

Requirements

Running the Server

Mock mode (no real device):

deno run --allow-net --allow-env main.ts

Real device mode (forwards /api/* calls to the actual Boiler Controller):

BC_DEVICE_IP="192.168.1.50" deno run --allow-net --allow-env main.ts

The server will start on http://localhost:8080. P1 simulation is always active, regardless of mode.

Boiler Controller API

Base URL: http://localhost:8080
API prefix: /api

GET /api/system

Returns device and runtime information.

{
  "system": {
    "firmwareVersion": 1,
    "cpuFrequency": "240 MHz",
    "ip": "192.168.1.123",
    "currentDateTime": "2026-04-23 20:15:00",
    "upSince": "2026-04-22 11:03:18",
    "wifiStrength": -58
  }
}

GET /api/status

Returns the current boiler status.

{
  "power": 1320,
  "heatingPercentage": 60,
  "temperature": 65.0,
  "total": 12345,
  "rssi": -50
}

GET /api/heat

Sets the heating percentage. The value is clamped to 0–100.

GET /api/heat?percentage=60

Response: OK

GET /api/reboot

Simulates an ESP reboot (resets boiler state to idle).

GET /api/reboot

Response: Restart ESP

GET /api/factoryreset

Simulates a factory reset (resets all state to defaults).

GET /api/factoryreset

Response: OK

POST /api/update

Accepts a firmware .bin file upload (mock: discards the body and returns OK).

POST /api/update
Content-Type: multipart/form-data

update=<firmware.bin>

Response: OK


Simulated P1 Meter

Stateful mock that lets clients poll a P1 reading while you adjust the scenario.

GET /p1/reading
GET /p1/change-scenario?scenario=mixed_clouds
GET /p1/change-scenario?scenario=swinging_grid&negative=true
Scenario key Description Expected range
sunny_export Steady export around −3 kW −3.2 kW – −2.8 kW
sunny_export_low Steady export around −1.5 kW −1.7 kW – −0.8 kW
mixed_clouds Cloud breaks causing swings between −4 kW and −1 kW −4 kW – −1 kW
swinging_grid Similar pattern but between −2 kW and +0.5 kW −2 kW – 0.5 kW

negative parameter (optional, keeps previous value if omitted)
Force the scenario watts to always be negative (exporting), regardless of the scenario's natural direction. Useful to simulate a solar surplus even in scenarios that can swing positive.

Value Effect
true / 1 / yes / on Force export (negative watts)
false / 0 / no / off Remove the override

The boiler's power consumption (driven by heatingPercentage) is automatically added to the P1 reading via externalLoadWatts.