11 changes: 11 additions & 0 deletions CHANGELOG.md
Original file line number Diff line number Diff line change
Expand Up @@ -10,6 +10,17 @@ Release notes for each tagged version are extracted from this file by the

## [Unreleased]

### Added
- **Operating modes (Auto / Manual).** New `Operating Mode` select switches
between the existing temperature-driven curve (**Auto**) and a new **Manual**
mode with a `Manual Fan` on/off switch and a `Manual Fan Speed` (0–100 %)
number. A single resolved-speed template sensor drives the PWM in both modes,
so `Fan Speed` always reflects the actual duty. Safety failsafes (NaN read,
>60 s sensor stall → 100 %) still apply in **all** modes, including Manual.
Mode + manual controls are grouped on the web UI via `web_server`
sorting groups (the stock UI can't hide entities by state, so they are shown
but inert in Auto).

### Changed
- Home Assistant transport switched from the native ESPHome **`api:` to
`mqtt:`** in `fancontrol.yaml`. The encrypted native-API block is now
Expand Down
15 changes: 15 additions & 0 deletions PROJECT_PLAN.md
Original file line number Diff line number Diff line change
Expand Up @@ -92,6 +92,21 @@ or the device won't join WiFi.
components with `restore_value: true` for user-tunable settings. No manual
NVS wrapping needed.

### F7 — Operating modes
- **Operating Mode** `select` (`Auto` / `Manual`, persisted). Default `Auto`.
- **Auto** — unchanged: temperature-driven 5-point fan curve, clamped to Fan Min %.
- **Manual** — **Manual Fan** `switch` (on/off) + **Manual Fan Speed** `number`
(0–100 %). Off forces 0 %.
- A single template sensor (`fan_speed_pct`) resolves the duty for both modes
and drives the PWM output, so "Fan Speed" always reflects the actual duty.
- **Safety overrides apply in all modes:** NaN sensor read and the >60 s
sensor-stall failsafe still force the fan to 100 % even in Manual. The
temperature alarm remains indicator-only (does not force the fan).
- The stock ESPHome web UI cannot hide entities by state, so manual controls
are always shown (inert in Auto); `web_server` sorting groups keep them
organised. Per-mode conditional UI, if wanted, belongs in a Home Assistant
dashboard keyed on the mode entity.

## 3. Architecture

One file, one responsibility:
Expand Down
20 changes: 18 additions & 2 deletions README.md
Original file line number Diff line number Diff line change
Expand Up @@ -74,18 +74,34 @@ broker — no manual entity setup needed. Exposed entities:
|---|---|---|
| Temperature | sensor | °C, from DHT22 |
| Humidity | sensor | %, from DHT22 |
| Fan Speed | sensor | % duty, derived from the curve |
| Fan Speed | sensor | % duty actually applied (curve in Auto, manual setting in Manual) |
| Fan PWM Frequency | sensor | Hz |
| Restart Counter | sensor | monotonic, persisted in NVS |
| Uptime | sensor | seconds |
| WiFi Signal | sensor | dBm |
| Temperature Alarm | binary_sensor | `safety` class, fires at the configured threshold |
| Sensor Alarm | binary_sensor | `problem` class, fires after 60 s of no successful reads |
| Operating Mode | select | `Auto` (curve) or `Manual`, persisted |
| Manual Fan | switch | on/off — Manual mode only |
| Manual Fan Speed | number | 0–100 % — Manual mode only |
| Alarm Temperature | number | tunable threshold |
| Fan Min % | number | minimum duty under normal operation |
| Fan Min % | number | minimum duty under normal operation (Auto) |
| Fan PWM Frequency Setting | number | 1000–5000 Hz, applied live via `ledc.set_frequency` |
| Restart / Factory Reset | button | standard ESPHome buttons |

## Operating modes

- **Auto** (default) — fan speed follows the temperature curve, clamped to `Fan Min %`.
- **Manual** — `Manual Fan` toggles the fan and `Manual Fan Speed` sets the duty
directly (off forces 0 %).

Safety failsafes apply in **both** modes: a NaN reading or a >60 s sensor stall
forces the fan to 100 %, even in Manual.

> The built-in ESPHome web page can't hide entities by mode, so the manual
> controls are always visible (they're simply inert in Auto). For per-mode UI,
> use a Home Assistant dashboard with conditional cards keyed on `Operating Mode`.

## Safety behaviour

- **Sensor stall** (no successful DHT22 read for 60 s) → fan forced to 100 %.
Expand Down
79 changes: 76 additions & 3 deletions fancontrol.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -91,6 +91,15 @@ mqtt:
web_server:
port: 80
version: 3
# The stock web UI cannot hide entities by state, so manual controls are
# always visible (they are simply inert in Auto mode). Groups keep it tidy.
sorting_groups:
- id: group_operation
name: "Operation"
sorting_weight: 10
- id: group_manual
name: "Manual control"
sorting_weight: 20

# -------- Globals (restore_value = persisted across reboots) --------

Expand Down Expand Up @@ -127,7 +136,8 @@ sensor:
filters:
- filter_out: nan

# Fan speed derived from the curve. Drives the PWM output via on_value.
# Resolved fan speed. Single driver of the PWM output (via on_value) for
# BOTH modes, so this sensor always reflects the actual duty being applied.
- platform: template
name: "Fan Speed"
id: fan_speed_pct
Expand All @@ -136,9 +146,21 @@ sensor:
update_interval: 1s
lambda: |-
const float t = id(dht_temperature).state;
if (std::isnan(t)) return 100.0f; // sensor warmup / NaN → failsafe bias
if (id(alarm_sensor_stall).state) return 100.0f; // SW watchdog stall

// Safety overrides apply in ALL modes (Auto and Manual). Preserve these.
if (std::isnan(t)) return 100.0f; // sensor warmup / NaN → failsafe
if (id(alarm_sensor_stall).state) return 100.0f; // SW watchdog stall → failsafe

// Manual mode: user-controlled on/off + speed. Off forces 0 %.
if (id(operating_mode).state == "Manual") {
if (!id(manual_fan_switch).state) return 0.0f;
float m = id(manual_fan_speed).state;
if (m < 0.0f) m = 0.0f;
if (m > 100.0f) m = 100.0f;
return m;
}

// Auto mode: temperature-driven curve (clamped to Fan Min %).
const float ts[5] = { ${curve_t0}, ${curve_t1}, ${curve_t2}, ${curve_t3}, ${curve_t4} };
const float ps[5] = { ${curve_p0}, ${curve_p1}, ${curve_p2}, ${curve_p3}, ${curve_p4} };

Expand Down Expand Up @@ -206,9 +228,60 @@ binary_sensor:
if (id(last_sensor_read_ms) == 0) return {};
return (millis() - id(last_sensor_read_ms)) > 60000;

# -------- Operating mode + manual controls --------

select:
- platform: template
name: "Operating Mode"
id: operating_mode
icon: mdi:fan-auto
web_server:
sorting_group_id: group_operation
optimistic: true
restore_value: true
initial_option: "Auto"
options:
- "Auto"
- "Manual"
# Recompute the resolved fan speed immediately on mode change.
on_value:
- component.update: fan_speed_pct

switch:
- platform: template
name: "Manual Fan"
id: manual_fan_switch
icon: mdi:fan
web_server:
sorting_group_id: group_manual
optimistic: true
restore_mode: RESTORE_DEFAULT_OFF
# Only takes effect in Manual mode; inert in Auto.
on_turn_on:
- component.update: fan_speed_pct
on_turn_off:
- component.update: fan_speed_pct

# -------- Tunable settings (number components, persisted via restore_value) --------

number:
- platform: template
name: "Manual Fan Speed"
id: manual_fan_speed
web_server:
sorting_group_id: group_manual
min_value: 0
max_value: 100
step: 1
unit_of_measurement: "%"
initial_value: 50
restore_value: true
optimistic: true
mode: slider
# Only takes effect in Manual mode (with Manual Fan on); inert in Auto.
on_value:
- component.update: fan_speed_pct

- platform: template
name: "Alarm Temperature"
id: alarm_temp_threshold
Expand Down